RTCA/DO-160 Testing

Dayton T. Brown, Inc. can test to RTCA/DO-160A, B, C, D, and E. RTCA/DO-160 covers standard procedures and environmental test criteria for testing airborne electronic equipment (avionics) for the entire spectrum of aircraft, from light general aviation aircraft and helicopters through to the “jumbo jet” and “supersonic transport” classes of aircraft. Coordinated with EUROCAE (European Organization for Civil Aviation Equipment), RTCA/DO-160D and its European twin, EUROCAE/ED-14D, are worded identically.

We can perform Emissions and Susceptibility testing to 40 GHz. Our equipment can generate Radiated Susceptibility fields well in excess of 200 V/m across the frequency range of 10 kHz to 40 GHz.

We are A2LA accredited for RTCA/DO-160 testing, and have large anechoic test chambers, with high current DC and AC sources available. New: DTB now also offers state-of-the-art lightning testing as part of our RTCA/DO-160 capabilities.

RTCA/DO-160 EMI TESTING & EMC TESTING CAPABILITIES:

Section 4, Temperature and Altitude
Section 5, Temperature Variation
Section 6, Humidity
Section 7, Operational Shocks and Crash Safety
Section 8, Vibration
Section 9, Explosion Proofness
Section 10, Waterproofness
Section 11, Fluids Susceptibility
Section 12, Sand and Dust
Section 13, Fungus Resistance
Section 14, Salt Spray
Section 15, Magnetic Effects
Section 16, Power Input
Section 17, Voltage Spike
Section 18, AF Conducted Susceptibility
Section 19, Inducted Signal Susceptibility
Section 20, Radiated and Conducted Susceptibility
Section 21, Radiated and Conducted Emissions
Section 22, Lightning Testing; Indirect Effects (Single Stroke, Multi-stroke and Multi-burst waveforms)
Section 23, Lightning Direct Effects*
Section 25, ESD
Section 24, Icing
Section 26, Fire, Flammability

*completed at a partner lab.


BOEING

D6-16050-4, D6-16050-5
D6-44588


AIRBUS

ABD0100.1.2
ABD0100.1.8


EMI / EMC Testing - European Standards

EN Testing

Dayton T. Brown, Inc. can perform testing to many standards for Emissions and Immunity. Some of these standards are:

EN EMISSIONS TESTING

EN 55011, CISPR 11
Radiated and Conducted Emissions testing of Industrial, Scientific, and Medical (ISM) equipment. Performed in OATS, GTEM, Shielded, and Anechoic Facilities

EN 55013, CISPR 13
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement. Performed in OATS, GTEM, and Shielded, Anechoic Facilities

EN 55014-1, CISPR 14-1
Radiated and Conducted Emissions testing of Household Appliances, Electric Tools and Similar Apparatus. Performed in OATS, GTEM, and Shielded, Anechoic Facilities

EN55015, CISPR 15
Measurement of Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment. Performed in OATS, GTEM, and Shielded, Anechoic Facilities

EN 55022, CISPR 25
Radiated and Conducted Emissions testing of Information Technology equipment. Performed in OATS, GTEM, Shielded, and Anechoic Facilities

EN 55025, CISPR 25
Radiated and Conducted Emissions testing of Automotive equipment. Performed in GTEM Shielded, and Anechoic Facilities

EN61000-4-20, IEC 61000-4-20
Emissions and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides, using GTEM Facility

EN61000-4-21, IEC 61000-4-21
Emissions and Immunity Testing – Reverberation chamber test methods

EN60601-1-2, IEC 60601-1-2
Emissions and Immunity testing of Medical Electrical Equipment

EN61000-6-3, IEC 61000-6-3
Emissions Testing for Residential, Commercial, and Light Industrial Environments.

EN61000-6-4, IEC 61000-6-4
Emissions Testing for Industrial Environments.

EN61326
Emissions and Immunity testing of Electrical equipment for measurement, control, and laboratory use.


EN IMMUNITY TESTING

EN 61000-4, IEC 61000-4, IEC 1000-4 EN61000-4-2, IEC 61000-4-2, IEC 1000-4-2
Electrostatic Discharge (ESD) Immunity Testing

EN61000-4-3, IEC 61000-4-3, IEC 1000-4-3
Radio Frequency Electromagnetic Field Radiated Immunity Testing, 80 MHz to 6 GHz, Testing in GTEM and Anechoic Facilities

EN61000-4-4, IEC 61000-4-4, IEC 1000-4-4
Electrical Fast Transient/Burst Immunity Testing

EN61000-4-5, IEC 61000-4-5, IEC 1000-4-5
Surge Immunity Testing

EN61000-4-6, IEC 61000-4-6, IEC 1000-4-6
Immunity to Conducted Disturbances, Induced by Radio Frequency Fields

EN61000-4-8, IEC 61000-4-8, IEC 1000-4-8
Power Frequency Magnetic Field Immunity Testing

EN61000-4-11, IEC 61000-4-11, IEC 1000-4-11
Voltage Dips, Short Interruptions and Voltage Variations Immunity Testing

EN61000-4-13, IEC 61000-4-13
Harmonics and Interharmonics Immunity Testing

EN61000-4-16, IEC 61000-4-16
Common Mode Disturbances Immunity Testing, DC to 150 kHz

EN61000-3-2, IEC 61000-3-2
Harmonic Current Emissions

EN61000-3-3, IEC 61000-3-3
Voltage Fluctuations and Flicker Measurements

EN61000-3-11, IEC 61000-3-11
Voltage Fluctuations and Flicker Measurements

EN61000-4-20, IEC 61000-4-20
Emissions and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides, using GTEM Facility

EN61000-4-21, IEC 61000-4-21
Emissions and Immunity Testing – Reverberation chamber test methods

EN60601-1-2
Emissions and Immunity testing of Medical Electrical Equipment

EN60601-1-2, IEC 60601-1-2
Emissions and Immunity testing of Medical Electrical Equipment

EN61000-6-1, IEC 61000-6-1
Immunity Testing for Residential, Commercial, and Light Industrial Environments.

EN61000-6-2, IEC 61000-6-2
Immunity Testing for Industrial Environments

EN 55014-2
Radiated and Conducted Immunity testing of Household Appliances, Electric Tools and Similar Apparatus. Performed in GTEM, Shielded, and Anechoic Facilities

EN61326
Emissions and Immunity testing of Electrical equipment for measurement, control, and laboratory use.


IEC TESTING

See EN testing.


Automotive EMI / EMC Testing

CISPR

CISPR25
Radiated and Conducted Emissions testing of Automotive equipment. Performed in GTEM Shielded, and Anechoic Facilities


ISO TESTING

ISO 11451
Radiated and Conducted Immunity testing of Vehicles

ISO 11452
Radiated and Conducted Immunity testing of Vehicle Components


SAE TESTING

SAE J551
Emissions and Immunity testing of Vehicles

SAE J1113
Emissions and Immunity testing of Vehicle Components. This is the standard automotive EMC standard for components in US automotive applications other than for “the big three”.

The test methods are:

J1113/2 Conducted Immunity
J1113/3 Conducted Immunity
J1113/4 Conducted Immunity
J1113/11 Transient Immunity
J1113/12 Transient Immunity
J1113/13 ESD
J1113/21 Radiated Immunity
J1113/22 Radiated Immunity
J1113/24 Radiated Immunity
J1113/25 Radiated Immunity
J1113/26 AC Power Frequency Immunity
J1113/27 Radiated Immunity
J1113/41 Radiated and Conducted Emissions
J1113/42 Conducted Transient Emissions


SAE J1445
Environmental, Dynamics, Electrical and EMC testing of Heavy-Duty Vehicles and Components.

SAE J1752

Radiated Emissions testing of integrated circuits using a TEM cell 150 kHz to 1 GHz Radiated Immunity testing from DC to 1.2 GHz with up to 500 Watts input power

Radiated Emissions testing of integrated circuits using a TEM cell 150 kHz to 1 GHz. TEM cel also rated for Radiated Immunity testing from DC to 1.2 GHz with up to 500 Watts input power



Ford

Dayton T. Brown, Inc. is A2LA and AEMCLAP accredited for Ford testing per Ford ES-XW7T-1A278-AC. These EMI / EMC tests are:

RI 112 Radiated Immunity, BCI Method
RI 114 Radiated Immunity, ALSE Method including testing to 600 V/m
RI 130 Radiated Immunity, Inductive Transients
RI 140 Radiated Immunity, Magnetic Field
RI 150 Radiated Immunity, Charging System
CI 210 Conducted Immunity, Continuous Disturbances
CI 220 Conducted Immunity,Transients
CI 230 Conducted Immunity, Power Cycling
CI 250 Conducted Immunity, Voltage Offset
CI 260 Conducted Immunity, Voltage Dropout
CI 270 Conducted Immunity, Voltage Overstress
CI 280 Conducted Immunity, ESD
RE 310 Radiated Emissions
CE 410 Conducted Transient Emissions
CE 420 Conducted Emissions


We also perform EMI / EMC testing to older versions of the Ford specification, including ES-XW7T-1A278-AB. We are approved by Ford for all parts of the –AB specification.

Radiated Immunity, BCI Method Radiated Immunity, ALSE Method

Radiated Immunity, BCI Method

Radiated Immunity, ALSE Method



General Motors

Dayton T. Brown, Inc. is A2LA and AEMCLAP accredited for GM testing per GMW 3097. These EMI / EMC tests are:

Emissions, Radiated, ALSE
Emissions, Conducted, Artificial Network
Immunity, Bulk Current Injection
Immunity, Radiated, ALSE
Immunity, Radiated, Reverb, Mode Tuning
Immunity, Magnetic Field
Transients, Conducted Emissions
Transients, Immunity, Power Lines
Transients, Immunity, I/O Lines
Transients, Immunity, Direct Capacitive Coupling to Sensor Lines
Transients, Immunity, 85V Direct Capacitor Coupling
ESD, Powered-On
ESD, Remote I/O
ESD, Handling
GM 3172 Testing


We also perform EMI / EMC testing to older versions of the GM standards.

Radiated Emissions, ALSE Conducted Emissions, Artificial Network

Radiated Emissions, ALSE

Conducted Emissions, Artificial Network



Toyota

EMI / EMC Testing to Toyota EMC and Electrical Standards:

TSC7006G
TSC7025G
TSC7026G
TSC7508G
TSC7514G


Nissan

EMI / EMC Testing to Nissan EMC and Electrical Standards:

28001NDS00-11
28180NDS00-6
28400NDS Series (Over 20 different specs, contact us with your specific requirements)


BMW

Testing to BMW GS95002


Cummins

EMI / EMC Testing to Cummins Diesel EMC and Electrical Standards:

CES 14113
CES 14121
CES 14161
CES 14232


Fiat

Testing to Fiat EMC and Electrical Standards:

7-Z0100    • 7-Z0440    • 7-Z0441
7-Z0443    • 7-Z0444    • 7-Z0445
7-Z0446    • 7-Z0449    • 7-Z0450
7-Z0455    • 7-Z0470    • 7-Z0471
7-Z0472    • 7-Z0480    • 7-Z0483
7-Z0484    • 7-Z0485    • 9.90110


Other Automotive Standards we can test to:

Freightliner 49-00085

Isuzu

John Deere JDQ 53.3

Paccar


Facilities and Equipment

Remote Site Surveys

Site Surveys Dayton T. Brown, Inc. has performed site surveys at a variety of locations. We have portable equipment and power sources to perform on site testing in most locations. We can perform surveys for:

Conducted Ambient DC to 1 GHz
Magnetic Field, DC to 30 MHz
Electric Field, 30 Hz to 40 GHz


Request a Quote Request a Quote

© Dayton T. Brown Inc. - Engineering & Test Division - 1175 Church Street, Bohemia, NY 11716 - Email: test@dtbtest.com - Phone: 800.837.8456  - Fax: 631.589.3648