Hydraulic General Purpose Component Test Stands
Hydraulic Component Test Stand Model A/F27T-10
The Dayton T. Brown, Inc. Model A/F27T-10 Hydraulic Component Test Stand is a self contained test system designed for manual and computer aided test and evaluation of wide variety of hydraulic and electrohydraulic components at operating pressures up to 8000 psi.
The Model A/F27T-10 Hydraulic Component Test Stand contains two supply and return circuits, one pneumatic static circuit, and one static proof circuit.
|
Fluid Test Circuits |
|
• Circuit 1:
|
60 gpm maximum flow
|
|
• Circuit 2: |
60 gpm maximum flow with directional control
|
|
• Pneumatic Static Circuit:
|
0 to 8,000 psig
|
|
• Static Proof Circuit:
|
0 to 16,000 psig
|
|
Performance Characteristics |
|
• Supply Pressure:
|
8000 psi maximum independently adjustable on all circuits
|
|
• Return Pressures: |
1500 psi maximum independently adjustable on all circuits (3000 psig max optional) |
|
• Pneumatic Static Circuit:
|
0 to 8,000 psig
|
|
• Static Proof Circuit:
|
0 to 16,000 psig
|
|
Facility Input Requirements |
|
• Electrical Power: |
440 to 480 VAC, 3-phase, 60 HZ, 250 amp |
|
• Cooling Water:
|
135 gpm at 70° F maximum inlet temperature, 10 psid minimum supply to return
|
|
Dimensions |
|
• Hydraulic Console: |
84 in.(W) x 48 in.(D) x 74 in.(H)
|
|
• Electronic Console:
|
25 in.(W) x 36 in.(D) x 72 in.(H)
|
Hydraulic Test System Model LE 6000R
DTB's Model LE6000R General Purpose Hydraulic Test System is designed for test and evaluation of wide variety of hydraulic and electrohydraulic components at pressures up to 6000 psi.
The LE 6000R Test System has three supply and return circuits, one leakage test circuit, and one static test circuit.
|
Fluid Test Circuits |
|
• Circuit 1:
|
90 gpm maximum flow
|
|
• Circuit 2: |
40 gpm maximum flow |
|
• Circuit 3
|
40 gpm maximum flow with directional control
|
|
• Leakage Circuit
|
30 cis maximum
|
|
• Static Proof Circuit:
|
0 to 10,000 psig (0 to 20,000 psig optional)
|
|
Performance Characteristics |
|
• Supply Pressure:
|
6000 psi maximum independently adjustable on all circuits
|
|
• Return Pressures: |
5000 psi maximum independently adjustable on all circuits |
|
• Temperature:
|
160 degrees F maximum
|
|
Facility Input Requirements |
|
• Electrical: |
120 VAC, 1-phase, 60 HZ, 15 amp |
|
|
120 VAC, 1-phase, 60 HZ, 15 amp Secondary Power
|
|
|
120 VAC, 1-phase, 60 HZ, 30 amp (Instrumentation)
|
|
|
|
|
• Hydraulic:
|
100 U.S. gpm maximum, 6000 psig maximum
|
|
Dimensions |
|
• Hydraulic Console: |
84 in.(W) x 48 in.(D) x 74 in.(H)
|
|
• Electronic Console:
|
25 in.(W) x 36 in.(D) x 72 in.(H)
|
|
|