Custom Hydraulic Test Stands
Model PRV Pressure Reducing Valve Test Stand
|
|
Pressure Reducing Valve Hydraulic
Test Stand
|
Radiator Hydraulic Test Stand |
|
PRV Hydraulic Test Stand Performance Characteristics |
|
• Supply Pressure:
|
450 to 5000 PSIG operating
|
|
|
Up to 6800 PSIG transient pressure
|
|
• Low Pressure Supply:
|
Adjustable from 1 to 30 PSIG
|
|
• Outlet Pressure:
|
Adjustable from 150 to 5000 PSIG |
|
• Return Pressure:
|
Adjustable from 10 to 150 PSIG
|
|
|
Up to 2500 PSIG transient pressure
|
|
• Static Proof Pressure: |
Up to 10,000 PSIG
|
|
• Supply Flow: |
60 GPM maximum
|
|
• Filtration |
3 microns absolute
|
|
PRV Hydraulic Test Stand Facility Input Requirements |
|
• Electrical Power:
|
460 VAC, 3 phase, 60Hz, 400 AMP |
|
• Cooling Water:
|
62 GPM@ 20 PSID, 80 degree F inlet
|
|
PRV Hydraulic Test Stand Dimensions |
|
• Test Stand: |
80 in. (W) x 70 in. (D) x 68.5 in. (H)
|
Radiator Flushing Hydraulic Test Stand
|
|
|
Water Pump Hydraulic Test Stand
|
Damper Hydraulic Test Stand |
|
Radiator Flushing Hydraulic Test Stand Performance Characteristics |
|
• Supply Pressure:
|
0-60 PSIG operating
|
|
• Supply Flow: |
1-20 GPM |
|
• Filtration
|
10 microns absolute
|
|
Radiator Flushing Hydraulic Test Stand Facility Input Requirements |
|
• Electrical Power:
|
460 VAC, 3 phase, 60Hz, 400 AMP
|
|
• Cooling Water:
|
25 GPM@ 20 PSID, 80 degree F inlet
|
|
Radiator Flushing Hydraulic Test Stand Dimensions |
|
• Test Stand: |
66 in. (W) x 96 in. (D) x 83 in. (H) |
|
|