Hydraulic Automated Pump Test Stand


Break-In Test Stand Model VP 5005BI


Automated Pump Test Stands: Model VP 5005BI Break-In Test Stand

Performance Characteristics
Pump Discharge Pressure: 5000 PSIG maximum
Pump Inlet Pressure: 500 PSIA maximum
Case Pressure: 500 PSIG maximum
Drive Horsepower (2): 50 HP at 6000 rpm each
Drive Speed: 14,000 rpm maximum
Flow Range: 0.15-25.0 GPM
Fluid Temperature: Ambient to 275 degrees F max
Filtration 3 microns absolute


Facility Input Requirements
  Electrical Power:
Test Stand: 460 VAC, 3 phase, 60Hz, 150 AMP
Inverter (x2): 460 VAC, 3 phase, 60Hz, 103 AMP
Operator's Console: 120 VAC, 1 phase 60Hz, 15 AMP
  Cooling Water:
Recirculation Loop: 20 GPM@ 20 PSID, 80 degree F inlet
Pump Loop A: 27 GPM@ 20 PSID, 80 degree F inlet
Pump Loop B: 27 GPM@ 20 PSID, 80 degree F inlet
Shop Air:
Input: 80 PSIG Minimum, 125 PSIG maximum
Consumption: 5 SCFM Nominal, 40 SCFM Peak
Dew Point: 40 degrees F maximum


Dimensions
Test Stand: 48 in. (W) x 120 in. (D) x 73 in. (H)
Operator's Console: 24 in. (W) x 46 in. (D) x 86 in. (H)
AC Inverter Cabinet (2): 32 in. (W) x 22 in. (D) x 88 in. (H)