1-800-TEST-456
 
Air force mechanic using a test stand for testing aircraft component Test stand valves and plugs Gear Box Aircraft mechanic working on an aircraft using aircraft fuel component test stand
Request a Quote Request a Quote


Certifications and Accreditation
 

Pneumatic Pressure Vacuum Pump Test Stand

Vacuum Pump Test Stand Model VPTS

Vacuum Pump Test Stand Model VPTS
Performance Characteristics
Speed Range: 0 to 8,000 rpm
Flow Range: 2.5 to 250 LPM
Vacuum Meausrement: 0 to 760 mm
Temperature Chamber: -40 Degrees C to 177 Degrees C
Shaft Torque Measurement: 0 to 10 N-M
Shaft Load, Radial (Upward): 0 to 2224 N
Shaft Load, Radial Spike (Upward): 2780 N Intermittent
Shaft Load, Axial (Bi-Directional): 0 to 445 N
Vacuum Circuit Volume: 1.0 to 6.0 Liters


Facility Input Requirements
  Electrical Power:
Test Stand: 460 VAC, 3 phase, 60Hz, 20 AMP
  Temperature Chamber:
Liquid Nitrogen (LN2): 35 PSIG maximum
Chamber Exhaust: 4.0" diameter
Shop Air:
Input: 95 PSIG Minimum, 125 PSIG maximum
Consumption: 5 SCFM Nominal, 40 SCFM Peak
Dew Point: 40 degrees F maximum


Dimensions
Test Stand: 83 in. (W) x 56 in. (D) x 88 in. (H)


Request a Quote Request a Quote

© Dayton T. Brown Inc. - Engineering & Test Division - 1175 Church Street, Bohemia, NY 11716 - Email: test@dtbtest.com - Phone: 800.837.8456  - Fax: 631.589.3648